I. Application
Surge protector with nominal discharge current over 60kA is suitable for surge protection of general power at important place.
20~40kA is suitable for surge protection of kinds of power system ( such ass USP power, machine room power). 5kA,10kA is suitable
for surge protection of kinds of device power. C+D, B+C model surge protector is suitable for surge protection of power supply system
with low-limited voltage. The surge protector is widely used for power system of mobile communication base station, telecom
machine room, factories, civil aviation, banking, such as power substation, transformer room, power distribution cabinet, switchbox
and other important devices need lightning protection.
II.Technical Data
Model |
KIN D15 |
Description |
220V、18mm |
Nominal Discharge Currents In(kA,8/20μs) |
20 |
Maximum Discharge Currents Imax(kA,8/20μs) |
40 |
Protection Level(kV) |
1.8 |
Respond Time (ns) |
≤25 |
Rated Voltage (VAC) |
220 |
Maximum Continuous Running Voltage (VAC) |
385 |
Drain Currents 0.75U 1mA(μA) |
≤20 |
Work Temperature (℃) |
-40~+85 |
Products Size (mm) |
90×36×66 |
III.Drawing for Fixation
IV. Fixation Instruction
Ø1. Must cut off the power before installation, no live action.
2. Lightning series in front of the module recommended fuse or automatic circuit breakers.
3. Installation according to the installation diagram shows connections, where L is the phase line, N is zero line, PE is ground,
do not pick the wrong. After installation is complete, close the automatic circuit breaker (fuse) switch, check the working
condition is normal.
4. Module is inserted in place after the installation is complete, check the lightning protection module is working properly.
5. Lightning protection module during use, should be monitored regularly and view fault status display window, when the fault
display red or remote communication terminal outputs an alarm signal, said the mine module fails, should be repaired or replaced.
6. Parallel lightning protection module should be installed in parallel (also can be Kevin wiring), cables require a solid and reliable,
and requires a short, thick, straight.
7. Non-professionals do not disassemble.